©Endress+Hauser
Dosimass for filling and bottling applications
©Endress+Hauser
Dosimass with batching functionality
Successor
Mass flowmeter with hygienic design, highest repeatability and a compact transmitter
Read more
Simple products
Easy to select, install and operate
Technical excellence
Simplicity
Standard products
Reliable, robust and low-maintenance
Technical excellence
Simplicity
High-end products
Highly functional and convenient
Technical excellence
Simplicity
Specialized products
Designed for demanding applications
Technical excellence
Simplicity
FLEX selections
Technical excellence
Simplicity
Fundamental selection
Meet your basic measurement needs
Technical excellence
Simplicity
Lean selection
Handle your core processes easily
Technical excellence
Simplicity
Extended selection
Optimize your processes with innovative technologies
Technical excellence
Simplicity
Xpert selection
Master your most challenging applications
Technical excellence
Simplicity
Product headline
The compact sensor with an ultra-compact transmitter. Measurement of liquids with the most diverse properties in continuous process control & batching applications.
Sensor features
High process safety – high measuring accuracy for different media in shortest filling time. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Nominal diameter: DN 8 to 25 (³⁄₈ to 1"). Various hygienic process connections, 3-A conform. CIP, SIP cleanable sensor.
Transmitter features
Versatile and time-saving wiring – plug connector. Fast commissioning – pre-configured devices. Automatic recovery of data for servicing. Robust, ultra‐compact transmitter housing. Pulse/frequency/switch output, Modbus RS485. Excellent and easily cleanable transmitter.
Wetted materials
Measuring tube: 1.4539 (904L) Connection: 1.4404 (316/316L)
Measured variables
Mass flow, density, temperature, volume flow
Max. measurement error
Mass flow (liquid): ±0.15 % Density (liquid): ±0.0005 g/cm³
Measuring range
0 to 18 000 kg/h (0 to 660 lb/min)
Medium temperature range
–40 to +125 °C (–40 to +257 °F) 150 °C allowed for 1 h
Ambient temperature range
–20 to +60 °C (–4 to +140 °F)
Sensor housing material
1.4301 (304), corrosion resistant
Transmitter housing material
Display/Operation
No local operation Configuration via operating tools possible
Outputs
Pulse/frequency/switch output (passive)
Other approvals and certificates
3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR 3-A
Most downloaded
Dosimass
Description of Device Parameters
English version - 01/2019
Coriolis flowmeter
EN
DE PL
More
31/01/2019
01/09/2015
Language:
English
Version:
31/01/2019
File size:
690.4 KB
File name:
GP01050DEN_0219.pdf
Dosimass
Modbus RS485
Operating Instructions
English version - 01/2019
Coriolis flowmeter
EN
DE
More
31/01/2019
01/02/2017
01/09/2015
13/08/2014
Language:
English
Version:
31/01/2019
File size:
1.5 MB
File name:
BA01320DEN_0419.pdf
40 documents
Dosimass
Technical Information
Coriolis flowmeter The compact sensor with an ultra-compact transmitter
EN
German French Italian Japanese Polish Chinese
Select other language
01/02/2017
01/09/2015
13/08/2014
01/10/2012
01/02/2011
Language:
English
Version:
01/02/2017
File size:
1.6 MB
File name:
TI00065DEN_1717.pdf
Dosimass
Modbus RS485
Operating Instructions
Coriolis flowmeter
EN
German
Select other language
31/01/2019
01/02/2017
01/09/2015
13/08/2014
Language:
English
Version:
31/01/2019
File size:
1.5 MB
File name:
BA01320DEN_0419.pdf
Dosimass
Operating Instructions
Coriolis flowmeter
EN
Czech German Spanish French Italian Japanese Polish Russian
Select other language
31/01/2019
01/02/2017
01/09/2015
13/08/2014
01/10/2012
Language:
English
Version:
31/01/2019
File size:
1.4 MB
File name:
BA00097DEN_1819.pdf
Dosimass
Description of Device Parameters
Coriolis flowmeter
EN
German Polish
Select other language
31/01/2019
01/09/2015
Language:
English
Version:
31/01/2019
File size:
690.4 KB
File name:
GP01050DEN_0219.pdf
Dosimass
Modbus RS485
Description of Device Parameters
Coriolis flowmeter
EN
German
Select other language
31/01/2019
01/09/2015
Language:
English
Version:
31/01/2019
File size:
905.3 KB
File name:
GP01047DEN_0219.pdf
Dosimass
Brief Operating Instructions
Coriolis flowmeter
EN
German Spanish French Italian Portuguese Chinese
Select other language
01/02/2017
01/09/2015
13/08/2014
01/10/2012
01/02/2011
Language:
English
Version:
01/02/2017
File size:
1.1 MB
File name:
KA00043DEN_0517.pdf
Replacing electronics module and small parts
Installation Instructions
Dosimass 8BE
EN
German
Select other language
15/11/2018
04/08/2009
Language:
English
Version:
15/11/2018
File size:
244 KB
File name:
EA00068DA2_0918.pdf
Adapter RSE8, RSE5, RSE4
Installation Instructions
Proline Dosimass, Dosimag
EN
German
Select other language
01/10/2018
14/04/2014
Language:
English
Version:
01/10/2018
File size:
297 KB
File name:
EA01104DA2_0218.pdf
Dosimass
ATEX:
II3G Ex nA IIC T5 to T1 Gc
Safety Instructions
Documentation for hazardous areas
EN
German French
Select other language
01/02/2017
01/09/2015
14/08/2014
01/10/2012
01/02/2011
Language:
English
Version:
01/02/2017
File size:
297.2 KB
File name:
XA00079DEN_1717.pdf
Flow, density, concentration, viscosity
Language:
English
Version:
04/11/2022
File size:
357.4 KB
File name:
SD02752DEN_0222-00.pdf
Search spare parts by number in drawing
12 spare parts & accessories
12 spare parts
12 accessories
Elect mod DOSIMASS 24VDC cpl packed
Drawing number
Order code
1
50106416
Kit 10 fuses 125 VAC 2A00 slow-blow
Drawing number
Order code
3
50106219
Gasket to cover D20 DOSIMASS EPDM
Drawing number
Order code
2
50104802
FXA service adapter Batchline packed
Drawing number
Order code
8
50106443
Adapter FXA291 Dosimag/Dosimass packed
Drawing number
Order code
8
71035809
Commubox FXA291 (Hardware)
Drawing number
Order code
9
51516983
Drawing number
Order code
10
8BE-
Drawing number
Order code
9
FXA193-
Adapter RSE4 8pol. -> 4pol. 4 wire
Drawing number
Order code
7
50107167
Adapter RSE5 8pol. ->5pol. 5 wire
Drawing number
Order code
6
50107168
Adapter RSE8 8pol. ->8pol. 5 wire
Drawing number
Order code
5
50107169
Connection cable RKWTN8-56/5 P92, 5m
Drawing number
Order code
4
50107895
We value your privacy
We use cookies to enhance your browsing experience, collect statistics to optimize site functionality, and deliver tailored advertisements or content.
By selecting "Accept all", you consent to our use of cookies.
For further details please review our cookie policy .
Customize
Accept only essential